Attached is the full report from H2 Analytics.
Below is a summary of the testing results, including dates they were conducted:
H2 Analytics Testing – 1/16/2025
Results:
- 10 minutes: Mean H2 concentration: 6.07 mg/L, Dose: 2.17 mg
- 20 minutes: Mean H2 concentration: 8.25 mg/L, Dose: 2.89 mg
Test Methods:
- Water: Distilled, temperature of 24.5°C ± 1.5°C, pH 6.52
- Test Equipment: SRI 8610C gas chromatograph, H2A-TE-3001 centrifuge
- Test Method: Static headspace analysis
- Process: The bottle was filled with ~350 mL of water, then subjected to either a 10-minute or 20-minute cycle. Samples were drawn and analyzed using a gas chromatograph for dissolved hydrogen concentration.