A Healthy Life Starts with Echo Revive
The Hydrogen Water Bath Machine
Thank you for purchasing the Echo Revive Hydrogen Water Bath Machine. In order to use this product properly and expertly, please read this manual carefully before use and keep it together safely with the warranty card.
Attention: Frequently rinsing the unit and changing the water is good for the performance and life of the machine.
Important: We suggest to hydrogenate the water 15 to 30 minutes and then take a bath.
Don’t run the hydrogen bath unit once you are in the water because skin and other particles could clog the machine.
Do NOT run the machine for longer than 60 minutes, or damage to it can occur.
Note: The units may have slight color and appearance variations. The instruction manual shows the H2-2800 as a demonstration unit. The usage method is the same for different models.
PRECAUTIONS:
1. Do not operate the machine near an open flame.
2. Use the machine only in well-ventilated areas, do not use it in small confined space. Your average room is acceptable.
3. Do not use bad quality water like tap water, plain water. Damage may occur.(Dissolved substances in water will damage the electrolysis cell. Only distilled water is suitable)
4. Do not open the unit or disassemble any portion of the machine.
5. Drain water out before transporting the machine.
6. It is normal if there is a little water leakage or visual appearing after shipping, this is absolutely normal from when the machine was being tested before shipping.
Specifications
Name: Echo Revive Hydrogen Water Bath Machine
Model:ZHDY-W13-A voltage:AC110V 50Hz
Rated power:<480 W
Size:(L*W*H)340*290*420 mm
Weight:15kg/40lbs
General Introduction
A Hydrogen generator is a kind of light-weight, high-efficiency, energy saving and environmental protection high-tech patented product, which electrolyzes pure water to produce high-purity hydrogen. The core SPE electrode of the machine is a highly active zero polar distance electrode formed by the combination of compound catalyst and ion membrane, with high electrolysis efficiency; it has a perfect electrical control system.
The machine has an advanced design, reliable quality, high automaticity, high purity of hydrogen and a wide range of applications
Working Principle
Electrolytic water (resistivity more than 2MΩ·cm) is put into the anode of the electrolysis tank, and the water is decomposed at the anode immediately after the device is power on: H2O=H++OH-, and the hydrogen ion (OH-) is released at the anode to form oxygen (O2), which is discharged from the anode and carries part of the water into the water tank, and the water can be reused. Oxygen is given out from the oxygen outlet through a small hole at the upper part of the tank. The hydrogen ion, in the form of hydrated ion (H+ - XH2O) ,passes through the SPE ion membrane with the electric field force and reaches the cathode to absorb electrons to form hydrogen (H2), and the water is discharged from the cathode and enters the gas-water separator, where most of the water delivered from the electrolytic tank is removed, and the hydrogen containing trace water is put out from the hydrogen outlet.
Technical Index:
Electrical Controls
The electrical control of the machine mainly consists of three parts: electrolytic power, control board and displayers. Turn on the power switch button, the machine circuit will be electrified to enter the standby state, and the pure water tank will be added with pure water above the minimum water level, and the working time of the tank can be controlled by pressing the (Increase) key or (Decrease) key on the touch screen.
After adjusting the time, press the (Start/Pause) key, and the tank starts working. The hydrogen flow meter shows the real-time hydrogen flow, and the hydrogen outlet puts out hydrogen normally. Besides, to ensure the normal operation of the machine, the machine has water shortage protection, high temperature protection and power limitation protection
Usage Requirements
5. 1 The hydrogen generator cannot be used in a single close room!
5. 2 The working conditions of the hydrogen generator are as follows
- a. Temperature 0-40°C;
- b. Humidity <85%;
- c. Power 110V 50-60HZ;
- d. Horizontal arranged, with the front panel of the machine
facing the operator for operation easily.
- e. No direct sunlight, no light fire;
- f. Good ventilation;
- j. Good grounding of the power;
5.3 The machine must be added water to the tank before usage for the first time, and wait 5 minutes after adding water and then turn on the machine!
5.4 Water quality requirements
Requiring the soft water (deionized water or secondary distilled water), water resistivity greater than 2MΩ ·cm; ions in the unqualified water will be deposited, blocking the small hole of electrode, resulting in motor scrap. Please remember! Or there'll be some consequences.
5.5 Requirement of water level in the water tank
Requiring the water tank to be filled with over 2/3 of the tank (about 7 1/2 cups)
(tank volume 2.0L).
5. 6 Water change and tank cleaning requirements
The tank should be kept clean. Even if the water is soft, microorganisms may grow and make the water turbid after using for a long time, which may affect the gas production and service life of the tank. It is required to discharge the water from the tank every 1 month of use, and wash the tank several times (after adding a small amount of new water, slightly shake the machine back and forth, left and right several times), so that the discharged water is clean and does not contain floccules.
5.7 During the transportation of the machine, no water should be contained in the water tank to prevent water from overflowing and damaging the electrical components.
5.8 The electrolytic tank shouldn’t be short of water during transportation.
5.9 When repairing the machine, the machine must be closed first. Don’t disassemble the machine chassis and other accessories when the machine is on and working to avoid to get an electric shock.
5.10 When replacing the fuse of the fuse, the machine must be turned off first and disconnect the power cord. The fuse model of the machine is F6A L220V, please do not use the wrong model for fear of fire.
Unpacking and Acceptance
To begin, check whether the machine is intact, and check whether the spare parts are complete according to the packing list. If there is any damage to the machine, please contact with the transportation unit and the manufacturer in time to solve the problem.
Installation and Usage
6. 2. 1 The working environment of the machine should be in accordance with 5. 2 of the manual.
6. 2. 2 Open the top cover of this machine tank and add deionized water or secondary distilled water, and let the liquid level height in the upper till the float floats in the water tank, and then close the top cover.
Attention: You must add water first and then turn on the machine to make sure the electrolytic tank is not short of water!
6. 2.3 Take the power cord in the spare parts to connect the power. Attention: The power must be well grounded.
6. 2.4 Turn on the power switch on the back panel, while the front panel screen lights up and enters the standby state.
6. 2.5 Take the suction tube from the spare part and plug it to the hydrogen outlet.
6. 2. 6 Click the Start/Pause switch at the bottom of the middle of the screen, and the hydrogen machine starts to produce hydrogen (the default timer is 15 minutes and the default hydrogen production is the first gear), then the countdown starts, and after the countdown ends, the machine enters the standby state.
6. 2. 7 Click the Start/Pause switch again, and the machine will enter the next timing cycle; the set time can be adjusted by yourself, the time "+" and "-" on the lower right corner of the screen. Each time you click "+", the set time will increase by 15 minutes, up to 60 minutes, each time you click "-", the set time will decrease by 15 minutes.
Attention: Avoid running the machine for longer than 60 minutes at a time to prevent the machine from overheating.
Alarm
7.1 Display "TDS is high,please reboot after changing water"
Alarm reason: Adding impure water or the water containing salt.
Solution: Discharge the water from the tank through the drain and add pure water again; it is better to change water several times and turn on the machine after cleaning the tank.
7.2 Display "Temperature is high"
Alarm reason: The temperature inside the machine reaches up to 70°C and it shows high temperature。
Solution: Please change the water or cool the machine for a period of time before using the machine again
7.3 Display: "Please check TDS sensor"
Alarm reason: TDS sensor is not recognized, and it may be not installed properly or it is damaged
7.4 Display "low water level"
Alarm reason: The water tank is running low, and more than half of the water tank needs to be filled.
7.5 Display: "Water level is high
Alarm reason: The water tank has too much water, exceeding the maximum water level.
Solution: Drain some water from the back drain hole.
7.6 Pump error
Alarm reason: Water pump pressure is blocked, or the pump is broken.
Solution: Please drain water with drain hole 2 for 2-3 mins while the machine is working, or change new pump.
7.7 It does need to change fuse if there is no red light working on the switch button.
How to replace the fuse: Use a flat-blade screwdriver to pry open the position as shown in the picture. After replacing the fuse (the fuse is installed regardless of direction), install it back to its original position, and the installation is complete.
7.8 Abnormal noise and idling sound of water pump
Solution: Please drain water with drain hole 2 for 2-3 mins while the machine is running to release pressure inside the pump.
After Sales Services
The machine comes with a full one-year warranty and has a lifelong maintenance. Within the warranty period, repair and replace parts for free. After the warranty period, only the cost of raw materials will be charged.
The following cases are not covered under warranty.
1 Violation of the manual use will not be warrantied.
2 The water’s resistivity should be > 2 M or electrolytic tank will damage, which is not be warranted (There are unclean materials on ion membrane platinum layer).
3 Without the manufacturer's permission, disassembly by yourself will not be warranted.
Add comment
Please sign in to leave a comment.